Cleaners Controls Filters General Pool/Spa Heat Pumps Heaters Lighting Pumps Robotic Cleaners Sanitization Step 3: Select model to register. If you vacuumed the floc residue into the filter, you should be able to remove most of it with a thorough backwashing of 5 minutes or so. Even with the cells reverse polarity feature, the scale will still form on the plates. New pump probably not a shaft seal problem, just loose clamp band or volute bolts. Once it finishes calibrating, cycle the Main Switch from AUTO to SUPER CHLORINATE and back to AUTO. Any thoughts? Air can enter pressure side if the water is not making it all the way to the top of the filter or chlorinator. I have a hayward superpump and upon starting the pump, it sucks the water into the pump basket but when it is filled with water the pump will start revving up and down. We have a Hayward ultra pro lx series pump for our above ground pool. Any idea what the next most likely culprit could be? If you need a new one in a few days, I would not consider getting one from Hayward, that could take a month. Hi it could be small wood chips stuck in the pump impeller. The hotel has an excellent location, close to a wonderful coral reef, lagoon with natural pool and sandy beach, outdoor swimming pool available all year round, private beach area, kitesurfing center and bar. Hi Joe, make sure that the pump shaft is spinning freely. Monday Friday, 8 AM 5 PM. I have a Haywood swim pro voyager and it is making a loud vibration noise. The 1.5 hp pump was so strong you couldnt stand in front of the single return, which is why I used smaller pump. I just replaced the flow switch and that solved one problem, but now Im only able to produce chlorine when the system is on Super Chlorinate. Be sure the wiring is tight on both ends. Next time it happens, check power on the timeclock, or inspect the motor, looking thru the visual motor check window (again, only on Intermatic clocks), if no power is getting to the clock, replace the breaker, and/or wiring. So I need any kind of advice or help you can give me, before I have to call someone out. It has been operating properly in its current setup for atleast 2 years (came with house). Could it have shut it self off from overheating? It is so poorly designed and the helper handle is basically useless because it bumps into the outlet flow tube and the jandy. Hi Rose, Its common that winterized pumps may freeze up, caused by a rust layer inside the motor. But the process seems to take way too long. Replace the seal in the same orientation as you removed it, and reassemble. Hi Frank, so it ran for weeks or more on 115V, when set to accept 230V, and then it started overheating, and then ran great for about a month, but now it makes no noise at all. Inground pool, 1 Bought new vac hose now own 3 Just disconnect wires, and replace. Why would the pump and Polaris stop working at the same time? Any ideas as to what could be the problem? Inspect for any damage to wires or wire casing. Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical Full membership to the IDM is for researchers who are fully committed to conducting their research in the IDM, preferably accommodated in the IDM complex, for 5 We would like to show you a description here but the site wont allow us. Even if it looks good, it could be bad. How can I secure the top to the filter so the water will not pour out of it while the pump is on filter mode? Thanks for the help. Try adding another inch of water. Also, if there is a GFCI outlet connected, perhaps it is tripped? I have a 2 speed motor and the high will not start at start up. No moisture. Relays are usually small cubes, about 1 square, sometimes black, sometimes clear, mounted on a circuit board. everything works well but the circulation is half as strong as my last pump.Tried everything,BACKWASH,checked for air leaks. Packing Pool Putty or Silicone around the fitting is a good fix, replacing the fitting is a better fix. Full membership to the IDM is for researchers who are fully committed to conducting their research in the IDM, preferably accommodated in the IDM complex, for 5 Fitness View More. Keeping the pump lid o-ring clean and well lubricated also helps, be sure to use a Teflon pool lube, and not any petroleum based (Vaseline), which makes the rubber soft and can cause cover sticking problems too. The box is reading no water flow and psi is just above 0. pool water analysis near me; camel leather reclining sectional; chiaogoo twist shorties set; 24 emsco resin hydro pickers garden system; pool cover 16x10 oval; Pump lid not on tight, gasket not lubed, or not positioned properly (superpump) Replace with the exact same MFD number printed on the capacitor. Finally, it could be making the noise at the burner orifice, if one or more is not fully spewing gas, or is not ignited like the rest. Now when we try to turn everything on the pump wont start at all and keeps tripping the breaker. also dont forget to connect the bare bonding wire, if you have one. You will get much more visibility by. I have a Hayward HeatPro model HP21104T. BTW, this can be caused from a water hammer effect, running the pump and then shutting off flow suddenly, or the fitting could have been overtightened to begin with, 7 years ago, and age caused it to give way. partially collapsed, or partially clogged skimmer line. However, when I check the connection at the wired, there is definetly juice there. Signature Custom Cabinetry, 240. Or maybe the glue that Im assuming is no longer working? The pump is only one year old. JavaScript is disabled. Hi John, sounds like a thermostat issue (or potentiometer for electronic heaters), although it could be another issue that just by coincidence happens when water is warm, like low flow rates. Hi Keri, I understand, with Hayward Valves, incl the most common top mounted sand filter valve SP0714T, have the Spider Gasket molded to the underside of the rotor. The same thing happened to the first one. You can assist by removing the back cover and placing a fan behind the motor and try again after a day. Or it could be a bad breaker, but usually not. If you are comfortable using a power meter, you can measure power at all these points, breaker, timer or switch, and motor. Also, DE filters need to be opened up and hosed down completely clean every 6-9 months, and then started up again with a full charge of DE powder. When impellers are clogged sometimes they surge. gives you instant access to PDF files. Pumps normal pressure and pulls enough volume to keep bakery full. If so, you may try to glue them in place with JB Weld or similar, and if that doesnt work, a new housing would be in order. You can remove the cartridge, reassemble the filter and run the system, just to verify that the cartridge is the problem. By following the steps listed below, the Aqua Rite can successfully be restored.To view this guide step by step on our website, visit:http://www.inyopools.com/HowToPage/how_to_troubleshoot_a_hayward_aqua_rite.aspx It only blows air but when I take the lid off water comes out and the basket over flows. Guess I was wrong. Is there a disconnected wire in the back of the motor? Fixing this issue can be tricky, so we suggest you get the help of a certified professional. Suggestions on what to do next. I just purchased a new pump and installed it but once all the hoses are connected even with the pump off the pump is leaking from the strainer housing. Every time I vacuum my pool and then back wash and rinse. I have a Hayward Power-Flo LX pump that went out and I bought the identical one thinking it would be an easy replacement. Also keep in mind that 1 lb of DE powder is not 16 oz of kitchen dry measure, but actually 32 oz (4 cups) of kitchen measure, because DE is so light and fluffy The normal unit of measure for 1 lb of DE powder is a 1 lb coffee can (or 4 8 oz cups). Any suggestions? Your pressure should be much lower, maybe 5-10 psi, without the cartridge in place. pull the water through. Inspect the circuit board, blow off with some air, and look closely at the 3 wires for any insects, spiderwebs or corrosion of any type. The capacitor is like the battery in your car its needed to help get the pump up to speed (3200 RPMs) fast. Im really uncertain exactly how to even look for a solution to my problem. Then tighten the pump lid very tight. "description": "Hayward Pool Heater Troubleshooting Guide - how to step by step approach to determining if the water supply, gas supply, electrical supply or a component of the heater is causing the issue. The trick is the little plug on the electrical panel MUST be moved to either 230 (up one) or to 115 (down). Any idea what the problem could be? Hello, we have a 2 speed Hayward Tgistar pump it just stopped running, I have east the breakers both at the controller and on the main panel, the pump is hot to the touch and will restart after about two minutes then shutdown again. New motor sounds like the thermal overload switch (located at 12 oclock in the rear of the motor) is shutting off the motor, which is usually not a good sign, and mostly means the pump is on its way out. If you like the Perflex filter, go with the Perflex EC75A, which is rated for 80 GPM, EC65A is only rated for 67 gpm. Blower vacuum switch closed when expected open error, If the blower prover switch is closed before blower start-up the control will not start the blower. Blocked air vents and no air flow is also a possibility. Look closely at the centrifugal switch on the rear of the shaft, to be sure its tight and is not missing parts (like the springs), engage the switch by hand (power off), to be sure that the stationary switch (located at 6 oclock) is disengaging, or the two copper tabs separate. And check that incoming power matches the voltage for the motor, as the motor can be switched to accept 110V or 220V, see wiring diagram on motor label. Drive Error is a major fault. I filled the pool to the level line, but the air bubbles stayed. Its just a trickle (as opposed to a spray)at this time. I set up to measure motor current, using 100amp, 100mv shunt, the current draw is 6.5 amps @241V (Pump pressure about 17-18 psi) I would suggest replacing the pump with the same exact pump, which is matched to your filter size presumably. Checked to see that there was no short in the wire with an ohms meter . Check for possible turbulence or obstructions inside of the flow T. Ensure there are at least 12 inches of straight pipe before the flow switch. What can we check. Don, melted shrouds can indicate that the something may be laying on the burner tray, causing flames to shoot out a little sideways, or something is laying on (or clogging) the heat exchanger, allowing hot gas to build up inside the heater, slowing down the exhaust rate. Hi Davy, I have a brand new Hayward motor/pump as shown above on your site. No air leaks and it only does this as the heater warms the water up during hot days. Loose wire connections or touching terminal connections cause sparking. 5. inspect all wires inside the back of motor, looking for one that is disconnected, cut, crimped, or two metal terminals touching each other. Hoses popping off could also indicate a high pressure problem after the filter, such as obstructed return lines, such as plugged or blocked wall returns, or closed valves. search, pool & drain cover safety Hi Jodi, that could be two things either the pump impeller is severely clogged, keeping the motor shaft from turning or if the shaft spins freely, it is likely the capacitor (black cylinder in rear of motor) that has failed. Professional Profile, View All If that is what is happening to you Im sorry, but your motor is probably gasping its last breaths. I immediately unplugged it and the plug was black and the extension Outlet was melted. I believe there a water volume calculator, that can help us size the motor, the originally company who installed is not in business. Could this be true? All check ok. Hi Bobby, so you have power at the motor, but no noise. A hum sound is usually associated with a bad capacitor (motor rear, 9 oclock), however the capacitor is a battery that is only used on start-up, and is released within a second of start-up, but still could be related. When it cools it automatically trys to start again and motor turns on after 3 seconds of humming. Inspect and tighten the suction and discharge connections using Teflon tape. A leaking shaft seal should not cause your filter pressure to decrease. from thoughts? Hi Mark, there are salt and ozone resistant shaft seals that can be used, the salt could be the problem, or it could be caused by a water-hammer effect, where flowing water is shut-ff suddenly by a closed valve on the return side, or turning a filter valve while the pump is running. HELP!!! Hi Dave..your honest opinion please..new 14000gal gunite pool with hayward sp3400vsp pump September 2014,ran a month winterized and ran fine for 3 years, when company came to open up the pool in 2017,pump stuck,installed new 3400@ $1200. The latest Lifestyle | Daily Life news, tips, opinion and advice from The Sydney Morning Herald covering life and relationships, beauty, fashion, health & wellbeing Following this procedure will identify News Reporter Reveals On Live TV That Shes Been Secretly Recording We would like to show you a description here but the site wont allow us. Everything coming in appears to be tight. It will start to run normal for 2-3 seconds. "image": {
I took out the filter cartridge and hosed it down replaced, emptied all the baskets but still no change, only one of the jets is pushing out water, but barely. I have an older Hayward Pool pump for an above ground pool. Inspect the gasket as well, for nicks, dry-rot or other damage that may affect the seal. Only thing I can think of, is the Key assy aligned properly when it was screwed back onto the valve body? Hi Matt, my first guess would be an air leak on the suction side, most typically a loose pump lid (or no o-ring lube), or loose pipe that comes into the front of the pump (or no thread sealant on the threaded fitting), or sometimes a leaky suction side valve, or low water level, stuck skimmer weir Second guess would be a broken impeller, detached from the motor shaft. Most Common areas include the pump lid (must be very tight, with lubed lid o-ring), and the threaded pipe that comes into the FRONT of the pump (must be very tight and sealed if loose, use Pool Putty to fix, or replace the fitting) the effluent or exit pipe fitting leaking will not draw air, that is on the pressure side not the suction side. The Intermatic T106M timeclock is the standard outdoor timeclock, then you can set it to run 12 hrs daily +/-, or as needed. If you see any damage, replace your flow switch. But just like any sort of equipment, even the most well-made products sometimes need repairs. If it an older installation, I would again check the water chemistry to make sure it is balanced correctly. Then the others are 2-high speed and 1-low speed wire see the diagram on this page: http://waterheatertimer.org/How-to-wire-Hayward-two-speed-pump.html. Was running fine. For a DE filter, pull out the grids and clean them off. Have you checked the cells voltage, amperage, or done anything other troubleshooting? Test to see if 120V (+/- 10%) is coming into the motor, on the two wire terminals. Is it likely to be the pump or the AutoChlor switches and timer (which I replaced last year)? The waterfall pump should be a simple system, just a suction line and a return line (no valves? Could be too big for the pipe size, although normally I would think that a 1hp should be fine, but do a wheel RPM test on the cleaner (28-32 RPM of the wheel is ideal), and bleed off excess water pressure at the wall fitting. Fans of space opera and world-building fantasies will find this first book in the series compelling, concluding with a powerful vision of world-changing gods and attempts to free Eden from its curse that conclude in a cliffhanger for future books to explore. I also noticed that the repaired motor Next year, June 21, 2021, is the date that VS (Variable Speed) pumps will be required, over 1-hp in size. Sounds like a leak from the shaft seal, although it could be dripping from the pipe carrying water out of the pump, running down and dripping off the bottom. 24V after the transformer is present. hayward blue essence troubleshooting . Step 3: Ensure that there isnt anything obstructing or blocking the flow. Ive never owned a pool before and didnt have any problems all summer until the last 2 weeks. 240v Input voltage is present. I backflushed the filter and pump would loose almost all water in basket. The pump keeps kicking off every 24 hours and I turn it back on by hitting filter. My pump was tripping the breaker after about three minutes (consistently when I reset the breaker and turned on the pump, same thing). If error occurs 10 times during a call for heat the control will go into lockout. which can clog the tiny gears, or wire issues, burned spots or chewed wires (ants). There is an internal fan, near the front of the motor, but it is inside and hard to see. If there is an external 2-speed timeclock, check the wiring, esp. Also check that the water level is high enough, and that a skimmer weir is not stuck in the up position, blocking water flow. I also have voltage (115 volts)on both sides of the fuse holder with no fuse installed. Check the usual spots for air coming into the pump, 1) the threaded pipe coming into the pump (did you use thread sealant? Remove the two wires connected to the capacitor, with a small flathead, or needle nose pliers. You only need to touch both terminals briefly with the tip of an insulated screwdriver, to discharge the capacitor. Thanks, good question. Shaft seal went out twice and I have a groove in the motor shaft now. You can, if possible, vacuum to waste by setting the multiport on the Drain to Waste setting, and then vacuuming fast you will discharge silty debris out of the pool. After the click, immediately push the diagnostic button 5 times to begin the recalibration stage. easier. Turn it off fully, then back on again. If you are plugging and unplugging the pump to turn it on/off that could cause the problem over time. Help. We would like to show you a description here but the site wont allow us. You find these in our valve parts department or use one of our multiport valve rebuild kits. So, when a pump is surging or pulsing, and not getting up to full head it is either starved for water, because of closed incoming valves, or too big of a pump for too small inlet pipes or because of air being pulled into the pump from air leaks or low water level in pool or from some obstruction in the lines, pipes or valves, a clog or something broken off I have found a Drain King useful in diagnosing such things, find at a hardware store, the 1.5-2 model, and connect to a garden hose, to pressurize pool systems and pipes, to look for leaks, or used as a water hammer to force clogs out, back the other way. Thanks A. Ray Davis When it gets up to speed, the switch is supposed to release the capacitor. Following this procedure will identify LibriVox About. Finally, could be that the voltage is not quite right, one of the legs (power wires) not providing enough power. On traditional intermatic time clocks, you also have to make sure the timer dogs are tight, or they can slip, use pliers to tighten the nut tighter to avoid. Have had it for 4-5 years and have had no issues. put on high speed. Hi Tim, If Assy A has a bad motor (test it? Make sure that the fitting that goes into the pump has no air leaks, which is the most common air leak area. It feels like its not doing what its supposed to do. Then sometimes with no rhyme or reason the pump shuts down and will not come back on until after I turn off and on all breakers. Ran fine as long as I didnt turn it off. If the blower prover switch opens during the postpurge cycle (heater is not firing) the control will display the error code. If you find out, I would check the owners manual for information related to your symptoms. Incorrect sizing can cause multiple problems, including low water flow. 9,000 gallon in ground pool. 14mm Magnetic Spark Plug Socket, The motor eventually started. If low flow is not caused by a clogged strainer, inspect the cleaner hose for pressure loss (leaks). Hi, if the switch wont flip to on, the timer tripper could be right at the point where it is about to trip, making it hard to turn to on. IF so, replace the fitting, or pack pool putty or silicone around the fitting, and leave it running for 24 hours, until the sealant sets up hard. You are using an out of date browser. Is it plug and play? Hi, my Hayward pump is about 5 years old. Ive done the reset and it still showing 4300. 1. Weve had our Hayward for four years now never had any problems.tonight my husband vacuumed the pool then back washed it. For the filter, its a common problem, but its usually solved with soaking the fingers in a DE filter cleaner solution, or acid. A less common cause of water out of the waste line is a broken Spring, under the handle, indicated by a floppy handle or difficulty turning the valve, I have a Hayward Super Pump it will run for about 1 to 2 hours and then it shuts off once it cools off for an hour or so I can turn it back on it will run again the water flow its good its just shuts off when it gets hot, Hi Steve; check that you have good air flow all around the pump, and above. I have a Hayward North Star that I rebuilt with new motor, shaft seal, all new rubber seals, impeller, and diffuser. You may have a partially clogged burner orifice, which is the brass spray tip on the end of the burner tube, where the gas shoots out of the manifold. Looks like Ill take it apart tomorrow to see if the impeller is going out or the ceramic bearing may be loose. But not likely, since its been there for years. Most heaters can operate on 120V/240V, either one. Any ideas? If it sounds loud and grumbly, that can be a sign of cavitation, being starved for water, from not enough water being supplied (it wants more). any advise would be appreciated . Air leaks are another source of priming issues. What am I missing? Likely not a problem with the pump itself. I would look on the capacitor and order a new one online, with the same MFD number, or call some local electric motor repair shop and see if they have one available. Thanks. Thinking its the compressor or really dont know at this point. I have tried a segmented hose and a one piece hose and when it starts to clean, it will clean for about 30 seconds and then there seems to be no water flowing into the pump. Remove C/B Assy. Make sure pump motor is set to accept 110V (may be wired to accept 220V), and that all wires for the cord are tight, and connected correctly to terminals L1 and L2, I have a hayward super pump model c48k2n143b1 sp2607x10a and i am trying to wire on the 115v but i dont have a switch to change from 220 or 115 and no diagram on the pump i try yesterday to pump work but was not pulling the water like it is suppose to and after 3 min the pump what very hot .. so i think it is on 220v are you able to help me. This worked well until about 4 years ago, when I replaced it with a similar pump, a Hayward sp2607x10. A corroded part will be rusted and will start to disintegrate over time. The wire size may depend on the distance of wire run. Thank you so much for taking time to answer all our concerns. Automatic reset is 60 minutes. Hi Anmarie, Could be the wrong type of sand, but not likely if the bag said Pool Filter Sand on the label. After Irma came through, we were without power for a week, the pump wont run on low speed and when it runs at high speed, it overheats after about an hour and shuts off. If it humms or buzzes, it could be a bad capacitor, in rear of motor, at 9 oclock. If the voltage between the orange and black is not 12VAC, you need to replace the rectifier or the board. Pump motors are continuous duty, meaning that they are meant for continuous operation, it wont harm the motor, or cause it to overheat. Please contact me at mbrad39972@hotmail.com. Some pumps are a bit difficult to remove, even when you have removed the right bolts/clamp sometimes they need to be pried apart with a screwdriver, to separate the pump. On a Hayward pump with clogged impeller, you can remove the basket, reach through the small hole with your fingers (pump off! What can I do? If not, but the shaft and impeller spin freely remove the start capacitor, normally located in the motor rear, at 9 oclock, and write down the MFD number, and then order one online, or at a local electric motor repair shop. We have all these parts here: https://www.intheswim.com/c/valve-parts, I Installed a new Hayward VCSB216V solar pump. Its a good piece of troubleshooting. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
Hi thanks for speedy reply the breaker is 20 amp with a GFCI. In a Quirked world where most people have a superpower-like uniqueness to them, His is among the most dangerous. Hi Curt, not especially uncommon, small stress cracks on the outlet port of the pump, about 1/4 long? A very thin layer of rust develops between the stator and the rotor inside the motor, and getting a 7/16 open end wrench on the end of the shaft, and working it back and forth, breaks the rust and frees up the shaft to spin. Pump had been working fine, but this week started making a kind of rhythmic buzzing sound while running. And 93, thats just the temp of the water, the flames are much hotter of course, thats what is melting the plastic. And that the top gasket seats well into the groove in the filter body before putting the lid on. Same with other sensors. IF the motor is turning over or starting, but no water pumps, it is usually an air leak from a loose pipe coming into the pump, or a loose pump lid. Click Here to View Replacement Aquarite Parts 25 This advanced blue media lasts for the life of the cartridge to inhibit the growth of bacteria on the pleated fabric that can foul and weaken a cartridge. Motor was replaced then gfci breaker replaced to Hayward recommended breaker (same breaker I had first time) still tripping on every 4-5 days , 10 days inconstant times but again 99% of the time overnight. ), is power, verify that power is leaving the timer and arriving at the motor.
},
1. When you see a quick spurt or spray of water when the pump shuts off, this is an area where air is entering the system, and causing priming problems. Blower vacuum switch open during post-purge error.